SIXISOL200/DC

ISOLATED TRANSDUCER WITH POWER SUPPLY AND ACTIVE OUTPUT
  • digital processing of the input signal
  • transducer for measurement DC current or voltage
  • allows unipolar and bipolar input and output signal
  • directly current measurements up to ±5A, voltage up to ±500V DC
  • ability to measure absolute values and inverted signal
  • conversion accuracy <0,1%
  • response time 1ms, per order up to 300ms
  • dielectric strength input / output / supply power 4kV
  • universal power supply 19 – 300V DC & 90 – 250V AC

€120.30 excl. VAT

SIXISOL200

ISOLATING CONVERTER FOR UNIPOLAR AND BIPOLAR SIGNALS WITH SWITCHABLE CALIBRATED RANGES
  • 24 calibrated ranges
  • isolation unipolar and bipolar signals
  • setting ranges by slid switches DIP on the board
  • digital processing and transfer A/D and D/A
  • response time: 1ms, adjustable to 100ms by switch
  • accuracy 0,1%
  • power supply 18VDC for loop-powered transmitter on input
  • dielectric strength input / output & supply power 4kV
  • auxiliary power supply 24VDC ± 25%

€120.30 excl. VAT

Rawet Studio2 3.2.

Current version of the program for setting up transmitters and other devices.

Description of parts

  • Rawet Studio Analog
    This part is designed for setting all converters with current output (except converter SET, which is out of production). It also can setting converters with analog output (current, voltage) type ISOL. Outside of this can also be configured relay TS, display DPR and also converter PHXC. It's recommended to use adapter AY-USB for communication.
     
  • RS485 ASCII
    We use the ASCII part for settings most of converters with RS485 ASCII output (except converter DSL, which is out of production). The application needs to comunnicate via a converter to RS 485, which looks like COM port in the PC. We recommend use the converters AY-USB/485.
     
  • RS485 ModBus RTU
    We use the ModBus part for settings most of converters with RS485 ModBus output. The application needs to comunnicate via a converter to RS 485, which looks like COM port in the PC. We recommend use the converters AY-USB/485.
     

Change in version 2

  • New user interface
  • Full support for new types of converters
  • New system update
  • Acceleration of application

System requirements

The application is made for Microsoft Windows operation system.

Requirements:

  • Microsoft Windows XP SP3, Windows Vista SP1 (32b i 64b edice), Windows 7 or highter edition)
  • Microsoft .NET Framework 2.0
  • 12 MB RAM a 4 MB free disk space.
  • Installed drivers for AK-USB (or another converter serial port to USB)

 

Frequetly Asked Questions (FAQ)

  • The device has been found, but report as unsupported
    You have used older machine that had an old concept and is no longer supported. To set this device, you must use old version of Rawet Studio.
  • I don't know, which COM port I have to use
    The easiest way is run Rawet Studio Start (orange icon) and click on button on the bottom labeled "Find COM port." If the application cannot find the port, try to verify drivers installation.
  • I have connected the device, but application cannot find it
    Check, that you use right part of application (Current output, RS 485 ASCII or ModBus). Output type is written on front label of device. Another problem is bad COM port or communication parameters. You can use function "Find the device" to get right communication parametrs (on ASCII or ModBus - current output devices aren't connected on a bus).
  • Device was found, but the program can not identify the type of application and cannot work
    The error is in the obsolete definition file. Try to put the menu Update. To update the application program it is necessary to assign administrator privileges over access to their own folder (for Security Policy modern Windows systems)..
  • There isn't right linearization files in a application folder
    Follow the same procedure as above.
  • The device is reported as unsupported
    Some devices are no longer in the new version to support. Therefore, use the older version of the program Rawet Studio
  • Why the program requires access to the internet
    Runs only check the latest version on the Internet. Also need connect to download linearization and definition files.

PX300

new In stock
Multi-purpose temperature and resistance transmitter with galvanic isolation
  • transmitter is mounted in a connection head DIN "B" dimension or any box
  • galvanic isolation input - output - power supply: 1200Vef
  • easy programming by AX-USB adapter (AY-USB) without power supply
  • Transmitter with 4..20mA ouput is designed for:
       - any thermocouple with linearization and cold junction compensation
       - any RTD sensor or resistance transmitter
       - thermistors, KTY, NTC..

€99.10 excl. VAT

PTP11

Temperature sensors for outdoor use, plastic connection head with nickel-coated brass stem, IP65, output 4…20mA, 0…10V or RS485 (ASCII or MODBUS).
  • for outdoor use, IP65, -50…+80°C
  • it can be use transmitters
       - PP200 with output 4…20mA
       - PP300 with output 0…10V
       - PPL100 with output ASCII or MODBUS
  • power supply by output loop 8…28V ss, ripple max. 0,5V
  • any measuring range <-50…+80>°C, min. span 50°C
  • accuracy ±0,5% from span (max. ±0,25°C)
  • another parameters are shown in the datasheet of used transmitter

€79.80 excl. VAT

ISOL400/DC

ISOLATED TRANSDUCER WITH POWER SUPPLY AND ACTIVE OUTPUT
  • analog measurement of the input signal
  • transducer for measurement DC current or voltage
  • allows unipolar and bipolar input and output signal
  • directly current measurements up to ±10A, voltage up to ±1000V DC
  • conversion accuracy <0,1%
  • response time 1ms
  • dielectric strength input / output / supply power 4kV
  • universal power supply 19 – 300V DC & 90 – 250V AC

€104.50 excl. VAT
  • two-state programmable switch for monitoring of electrical values or temperature
  • output relay with changeover contact
  • Possibility of easy setting of switching value by potentiometer or programmed
  • input only RTD, R
  • supply voltage: 12V / 24V DC ± 25% without galvanic isolation
  • DIN rail mounting
  • the temperature adjusting element is inside the housing

€99.40 excl. VAT

AC24

AC TRUE RMS CURRENT OR VOLTAGE TRANSDUCER LOOP-POWERED
  • analog measurement
  • true RMS value of current or voltage
  • signal processing with crest factor up 10
  • frequency range 40 … 1000Hz
  • conversion accuracy  0,5%
  • response time 300ms
  • isolation input-output-power supply: 4000Vef
  • loop-powered

€112.40 excl. VAT

PMA300

In stock
Programmable transmitter for small temperature head "MAA" without galvanic isolation
  • transmitter is mounted in a connection head DIN "MAA" dimension or any box
  • easy programming by AX-USB adapter (AY-USB) without power supply
  • it converts temperature from RTD thermometer to 4..20mA
  • transmitter can be set for sensors Pt100/Ni100 or Pt1000/Ni1000

€67.10 excl. VAT

PT12

Temperature sensors for outdoor use with slow response, sensor is inside the plastic box, IP65.
  • it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
  • for outdoor use, IP65, -50…+100°C

€23.00 excl. VAT

PP210S

In stock
  • converter without galvanic isolation
  • transmitter with 4-20mA otput is designed for transduction:
       - voltage from any thermocouple with linearization and cold junction compensation
       - temperature from RTD or resistance from resistance transmitter
  • easy programming by AX-USB adapter (AY-USB) without power supply
  • power supply by output loop 11…30V DC, any polarity
  • slim design, DIN 35 rail-mounted, width 12,5mm

€70.40 excl. VAT

AC24/R

new
ISOLATED TRANSDUCER OF AC CURRENT OR VOLTAGE FOR RAILWAY APPLICATIONS
  • 4-20mA loop-powered
  • rated impuls voltage Uni: 8kV
  • analog measurement of the input signal
  • transducer for measurement RMS value of AC current or voltage
  • signal processing  with crest factor of 10
  • frequency range 40 až 1000Hz
  • accuracy <0,5%
  • response time 300ms
  • dielectric strenght  Ua input / output: 4kVrms
  • clearances and creepage distances min. 8mm
  • designed for DIN 35 rail mounting

€132.50 excl. VAT

Sada pH pufrů

Sada kalibračních roztoků pro měření pH
  • sada nejčastěji používaných pufrů 4,01 - 7,00 - 9,18 pH
  • barvené provedení usnadní rozlišení při kalibraci
  • 4,01 oranžový, 7,00 zelený, 9,18 modrý
  • balení 100 ml PET lahve
  • jmenovité hodnoty pH platí při +25°C
  • roztoky jsou dodávány příslušnými certifikáty a bezpečnostními listy

€18.40 excl. VAT

PT37 max. +200°C

Leads are made from stranded wire with PTFE insulation. Stem is made from  stainless steel 17248, optional dimensions and design.
  • stem from stainless steel diameter 5, 4 or 3mm, min. length 15mm
  • it can be use Pt100/A, B, from two to four wire connection, double sensor, Pt1000, Ni1000, KTY, PTC, thermocouples…
  • temperature range -40…+200°C
  • dielectric strength: 500V, insulation resistance min. 20MΩ (circuit to metal parts)

from €22.00 excl. VAT

PPL100

In stock
Digital temperature transmitter with RS485 otput without galvanic isolation
  • transmitter is mounted in a connection head DIN "B" dimension or any box
  • it converts temperature from Pt100, Pt1000 or Ni1000 sensor to digital otput RS485
  • transmitter has auto-recognize for Pt100 or Pt1000 sensors
  • we can set it for other input signals too
  • communication by RS485 line with master device on baud rate 600..19200Bd

€64.70 excl. VAT

PP210S

In stock
  • converter without galvanic isolation
  • transmitter with 0-10V otput is designed for transduction:
       - temperature from RTD or resistance from resistance transmitter
  • easy programming by AX-USB adapter (AY-USB) without power supply
  • power supply 12…30V DC
  • slim design, DIN 35 rail-mounted, width 12,5mm

€70.40 excl. VAT

AC24/S

AC MEAN VALUE CURRENT OR VOLTAGE TRANSDUCER LOOP-POWERED
  • current or voltage analog measurement
  • rectifier method of measuring the mean value
  • average value calibrated to RMS of sine wave
  • frequency range 40 … 1000Hz
  • conversion accuracy  0,5%
  • response time 300ms
  • isolation input-output:  4000Vef

€112.40 excl. VAT