Rawet s.r.o.
Manufacturing of regulation and measurement technology, transducers, temperature sensors.
Čapkova 22, 678 01 Blansko  Česká republika
+420 516 416 942 rawet@rawet.cz
Ověřená firma - ekatalog.cz ISO 9001:2008

Products

Total 252 items

GXN

ONE-RANGE ISOLATING CONVERTER WITH AUXILIARY POWER SUPPLY
  • one- range converter
  • isolation standard unipolar and bipolar signals
  • digital processing and transfer A/D and D/A
  • response time: 1ms, for order up to 300ms
  • accuracy 0,1%
  • power supply 18VDC for loop-powered transmitter on input
  • dielectric strength input / output / supply power 4kV
  • auxiliary power supply in wide range 19 to 300VDC & 90 to 250VAC

€115.70 excl. VAT

DPR40 xxx 2X

Programmable digital display - in design for DIN rail
  • power supply 19..300VDC & 90..250VAC with galvanic separation 4kV
  • measurements
    • RTD, Tc, R, U, I
    • unified signals 0-20mA, 4-20mA, 0-10V ....etc.
    • voltage or current DC
  •  output 1x relay or analog output 0-20mA, 4-20mA, 0-10V
  • 4 digit red LED
  • design for DIN rail
  • to display the measured value
  • monitoring of exceeding the set value

from €106.70 excl. VAT

PPL100

In stock
Digital temperature transmitter with RS485 otput without galvanic isolation
  • transmitter is mounted in a connection head DIN "B" dimension or any box
  • it converts temperature from Pt100, Pt1000 or Ni1000 sensor to digital otput RS485
  • transmitter has auto-recognize for Pt100 or Pt1000 sensors
  • we can set it for other input signals too
  • communication by RS485 line with master device on baud rate 600..19200Bd

€65.10 excl. VAT

PP210S

In stock
  • converter without galvanic isolation
  • transmitter with 0-10V otput is designed for transduction:
       - temperature from RTD or resistance from resistance transmitter
  • easy programming by AX-USB adapter (AY-USB) without power supply
  • power supply 12…30V DC
  • slim design, DIN 35 rail-mounted, width 12,5mm

€70.80 excl. VAT

AC24/S

AC MEAN VALUE CURRENT OR VOLTAGE TRANSDUCER LOOP-POWERED
  • current or voltage analog measurement
  • rectifier method of measuring the mean value
  • average value calibrated to RMS of sine wave
  • frequency range 40 … 1000Hz
  • conversion accuracy  0,5%
  • response time 300ms
  • isolation input-output:  4000Vef

€113.10 excl. VAT

PX24

ONE-RANGE ISOLATING CONVERTER LOOP-POWERED
  • loop- powered 4..20mA
  • input standard unipolar and bipolar signals
  • one-range converter
  • response time: 1ms
  • accuracy 0,2%
  • dielectric strength input / output 4kV

€106.10 excl. VAT

PI121

AC MEAN VALUE CURRENT TRANSDUCER
  • analog current measurement
  • rectifier method of measuring the mean value
  • average value calibrated to RMS of sine wave
  • frequency range 40 … 1000Hz
  • conversion accuracy  0,5%
  • response time 300ms
  • isolation input-output: 4000Vef
  • self powered from input current for output 0..20mA
  • loop-powered for output 4..20mA

€82.50 excl. VAT
  • two-state programmable switch for monitoring of electrical values or temperature
  • output relay with changeover contact
  • Possibility of easy setting of switching value by potentiometer or programmed
  • supply voltage 230V AC ± 10% (45 - 65 Hz) (transformer)
  • isolation strength input / output / power 4kV
  • DIN rail mounting
  • the temperature adjusting element is inside the housing

€110.80 excl. VAT

PX310

In stock
  • converter with galvanic isolation 4000Veff
  • it is designed for transduction:
       - temperature from any thermocouple with linearization and cold junction compensation
       - temperature from RTD or resistance from resistance transmitter
       - voltage 0-1V DC
  • easy programming by AX-USB adapter (AY-USB)
  • power supply 8…30V DC
  • DIN 35 rail-mounted design

€107.10 excl. VAT

PXL310

ISOLATED TRANSDUCER WITH POWER SUPPLY AND OUTPUT RS485 MODBUS
  • programmable converter with galvanic isolation 4000Veff input - output - power supply
  • it is designed for transduction:
        DC voltage up to 540V
        DC current 0..23mA, after an agreement up to 5A
  • communication by RS485 line with master device on baud rate 600..19200Bd
  • typically max. 56 transmitters on the line, distance max. 1200m
  • communication protocol ASCII or MODBUS-RTU

€124.10 excl. VAT

GXNB

ISOLATION CONVERTER WITH LIGHTNING IMPROVED RESISTANCE
  • isolation converter GXN with lightning improved resistance
  • one-range converter
  • converter provides additional protection lightning arresters and wire resistors in inputs and outputs
  • response time: 1ms
  • accuracy 0,1%
  • power supply 18VDC for loop-powered transmitter on input
  • dielectric strength input / output / supply power 4kV
  • auxiliary power supply in wide range 19 to 300VDC & 90 to 250VAC

€131.80 excl. VAT

eCon

Programming of  N20, N21, N24, N25 ... and others

PI121P

AC MEAN VALUE CURRENT TRANSDUCER
  • direct analog current measurement up to 100A
  • current threaded through
  • rectifier method of measuring the mean value
  • average value calibrated to RMS of sine wave
  • frequency range 40 … 1000Hz
  • conversion accuracy  0,5%
  • response time 300ms
  • isolation input-output: 4000Vef
  • self powered from input current for output 0..20mA
  • loop-powered for output 4..20mA

€82.50 excl. VAT

PX310S

In stock
  • converter with galvanic isolation 3700Veff
  • it is designed for transduction:
       - temperature from any thermocouple with linearization and cold junction compensation
       - temperature from RTD or resistance from resistance transmitter
       - voltage 0-1V DC
  • easy programming by AX-USB adapter (AY-USB)
  • power supply 8…30V DC
  • slim design, DIN 35 rail-mounted, width 12,5mm

€106.70 excl. VAT
  • two-state programmable temperature monitor
  • compact design, IP 65 protection
  • output relay with changeover contact
  • Possibility of easy setting of switching value by potentiometer or programmed
  • power voltage:
        12V / 24V DC ± 25% without galvanic isolation
        24V DC ± 10% with galvanic isolation 3kV
        230V AC ± 10% (45 - 65 Hz) (transformer)
  • isolation strength input / output / power 4kV
  • the temperature adjusting element is inside the housing
  • It is intended especially for monitoring of exceeding the set value, when the output relay switches (opens).
        (Eg when the air temperature drops below the set limit of + 4 ° C the heating is switched on).

€109.50 excl. VAT

PXL312

ISOLATED TRANSDUCER WITH POWER SUPPLY AND OUTPUT RS485 MODBUS
  • two-channel programmable converter 
  • with galvanic isolation 4000Veff input - output - power supply
  • inputs are galvanic isolated max. 1000V!
  • is designed for transduction:
        DC voltage up to 540V
        DC current 0..23mA, after an agreement up to 5A  
  • communication by RS485 line with master device on baud rate 600..19200Bd
  • typically max. 56 transmitters on the line, distance max. 1200m
  • communication protocol ASCII or MODBUS-RTU

€165.40 excl. VAT