- thermowells
- adjustable threads
- welded-on pieces
- holder for air conditioning
Related products - PT50N
(You can see description of sensors after click on Types, detailed tables are below)
Type |
Description |
TCR [ppm/°C] |
Tolerance [°C] |
Max. temp. [°C] |
|
A |
B |
||||
Platinum sensor 100Ω / 0°C |
3851 |
0,15+0,002t |
0,30+0,005t |
-70..+600 |
|
Platinum sensor 1000Ω / 0°C |
3851 |
0,15+0,002t |
0,30+0,005t |
-70..600 |
|
Nickel sensor 100Ω / 0°C |
6180 |
0,20+0,0035t |
0,40+0,007t |
-60..+250 |
|
Nickel sensor 1000Ω / 0°C |
6180 |
0,20+0,0035t |
0,40+0,007t |
-60..+250 |
|
Nickel sensor 1000Ω / 0°C |
5000 |
0,20+0,0035t |
0,40+0,007t |
-60..+250 |
|
Termocouple Fe-Ko |
c. 5,37mV/100°C |
-200..+750 |
|||
Termocouple Ch-A |
c. 4,80mV/100°C |
-200..+1200 |
|||
Termistor NTC (variety of) |
nonlinear |
±2..±5% |
-40..+125 |
||
Thermistor PTC with T sens |
nonlinear |
±5°C |
max. +180 |
||
Linear semicond. sensor |
c. 0,79%/K |
±1 .. ±5°C |
-55..+150 (+300) |
||
Sensor SMARTEC |
- |
±0,7°C |
-45..+130 |
||
Sensor DALLAS |
- |
±0,5°C |
-10..+85 |
||
Ton=+45..+145°C (by 5°C) |
- |
Ts ±5°C |
145 |
||
Toff=+45..+145°C (by 5°C) |
- |
Ts ±5°C |
145 |
Attachment for downloads:
(in TXT format for easy linearization in PC)
PP300RTD
- převodník je určen do hlavice teploměru rozměr DIN „B“
- uživatelská konfigurace převodníku
- převodník s výstupem 0-10V je určen k převodu signálu z Pt100, Pt1000, Ni100 a Ni1000,
- PP200 is mounted in a connection head DIN "B" dimension or any box
- converter without galvanic isolation, converts temperature from RTD to 4..20mA
- easy programming range by AX-USB adapter (AY-USB) without power supply
- the transmitter can be programmed for the types of sensors: Pt100, Pt1000, Ni 100, Ni 1000, KTY81..
PP300
- transmitter is mounted in a connection head DIN "B" dimension or any box
- easy programming by AX-USB adapter (AY-USB) without power supply
- transmitter with 0..10V ouput is designed for:
- any RTD sensor, resistance transmitter or potentiometer 0..100Ω, 0..1kΩ and 0..10 kΩ
- voltage 0..10V, thermistors..
- transmitter is mounted in a connection head DIN "B" dimension or any box
- galvanic isolation input - output - power supply: 1200Vef
- easy programming by AX-USB adapter (AY-USB) without power supply
- Transmitter with 4..20mA ouput is designed for:
- any thermocouple with linearization and cold junction compensation
- any RTD sensor or resistance transmitter
- thermistors, KTY, NTC..
PMA300
In stock- transmitter is mounted in a connection head DIN "B" dimension or any box
- it converts temperature from Pt100, Pt1000 or Ni1000 sensor to digital otput RS485
- transmitter has auto-recognize for Pt100 or Pt1000 sensors
- we can set it for other input signals too
- communication by RS485 line with master device on baud rate 600..19200Bd